Multi-one Dy517 Electronic Air Conditioner Refrigerant Meter Car Air Conditioner Repair Home Refrigerant Charging Meter
Multi-one Dy517 Electronic Air Conditioner Refrigerant Meter Car Air Conditioner Repair Home Refrigerant Charging Meter
Multi-one Dy517 Electronic Air Conditioner Refrigerant Meter Car Air Conditioner Repair Home Refrigerant Charging Meter
Multi-one Dy517 Electronic Air Conditioner Refrigerant Meter Car Air Conditioner Repair Home Refrigerant Charging Meter
Multi-one Dy517 Electronic Air Conditioner Refrigerant Meter Car Air Conditioner Repair Home Refrigerant Charging Meter

Multi-one Dy517 Electronic Air Conditioner Refrigerant Meter Car Air Conditioner Repair Home Refrigerant Charging Meter

5.0
682 sold.
Minimum quantity is: 1 pcs

Price from:

1,316,577 so'm

Guaranteed delivery time

If we are 45 days late, you will receive your order for free. More details

Always in touch with you

We will answer any questions every day.

Secure payment in a convenient way

We will accept payment by any card

BNPL available

Uzum
select product
inTend
select product
Select payment by installments when placing your order. The final installment cost is calculated at checkout.
Multi-one Dy517 Electronic Air Conditioner Refrigerant Meter Car Air Conditioner Repair Home Refrigerant Charging Meter

About the product

Characteristic

Origin

Guangdong

Type

Other

Brand

one more

Model

DY517

detection system

Car air conditioner household air conditioner

Whether to import

No

Processing customization

No

Dimensions

220*140*70

Power supply voltage

5

Description

 

.

DY517英文版主机+2个温度夹 :635*320*550   一件16台  23.5KG; 1台 尺寸:18.5*12*26.5 cm.  重量:1.5kg

 

The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout, multi-unit switching, multi-mode function and built-in refrigerant database. The instrument uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability. Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation. Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.


The instrument can measure double pressure (gauge pressure) at the same time, as well as dual temperature measurement (need test clip,not include), with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs. Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data. Also it tests percentage of vacuum measurement; pressure leak measurement, leak time speed record. It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right.


EC/EN61010-1 safety standards for design and production.
1) The pressure measured by the  digtal manifold pressure tester is gauge pressure.
2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3) The limit pressure is 10 Mpa (100 bar).
4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5) Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed
hoses does not match the pressure requirement, you can use suitable replacements for testing.
6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8) Please wear qualified protective equipment to protect user during testing.
9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.


Product specifications
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6)  Battery not include
Dimensions: 170*110*50mm weight: 950g

Packing list:
1x Refrigerantion Digital Manifold Gauge
1x User manual (in English)
Battery not include

 undefined

undefined

undefined

undefined

undefined

undefined

undefined



undefined





undefined

















06575c47-6fff-4a26-8c05-77d06249137d

 

.

SSCSC

sDfDSF

Packaging Details
  •  

Characters

Properties

Origin

Guangdong

Type

Other

Brand

one more

Model

DY517

Description

 

.

DY517英文版主机+2个温度夹 :635*320*550   一件16台  23.5KG; 1台 尺寸:18.5*12*26.5 cm.  重量:1.5kg

 

The intelligent electronic refrigerant group instrument is an auxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout, multi-unit switching, multi-mode function and built-in refrigerant database. The instrument uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability. Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation. Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.


The instrument can measure double pressure (gauge pressure) at the same time, as well as dual temperature measurement (need test clip,not include), with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs. Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data. Also it tests percentage of vacuum measurement; pressure leak measurement, leak time speed record. It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right.


EC/EN61010-1 safety standards for design and production.
1) The pressure measured by the  digtal manifold pressure tester is gauge pressure.
2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3) The limit pressure is 10 Mpa (100 bar).
4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5) Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed
hoses does not match the pressure requirement, you can use suitable replacements for testing.
6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8) Please wear qualified protective equipment to protect user during testing.
9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.


Product specifications
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6)  Battery not include
Dimensions: 170*110*50mm weight: 950g

Packing list:
1x Refrigerantion Digital Manifold Gauge
1x User manual (in English)
Battery not include

 undefined

undefined

undefined

undefined

undefined

undefined

undefined



undefined





undefined

















06575c47-6fff-4a26-8c05-77d06249137d

 

.

SSCSC

sDfDSF

Packaging Details
  •  

From this seller

View all