H56 Voltage Relay/0-100v Upper and Lower Limit Detection Control Switch / over and under Voltage Protection Charge and Discharge Timing

H56 Voltage Relay/0-100v Upper and Lower Limit Detection Control Switch / over and under Voltage Protection Charge and Discharge Timing

5.0
0 sold.
Minimum quantity is: 1 pcs

Price from:

136,360 so'm

Guaranteed delivery time

If we are 45 days late, you will receive your order for free. More details

Always in touch with you

We will answer any questions every day.

Secure payment in a convenient way

We will accept payment by any card

BNPL available

Uzum
select product
inTend
select product
Select payment by installments when placing your order. The final installment cost is calculated at checkout.
H56 Voltage Relay/0-100v Upper and Lower Limit Detection Control Switch / over and under Voltage Protection Charge and Discharge Timing

About the product

Characteristic

Brand

HZY

Model

H56UR

Whether to import

Processing and customization

Processing and customization

Processing and customization

Description

       本产品主要由智能直流电压表和直流继电器控制模块组成,既实现了对直流电压的精确测量,又可根据电压的上下限设定值、继电器动作延时值、计时时间和定时循环等参数进行多种组合,简单、灵活地实现了多种系统控制。广泛应用于电瓶充放电控制(逆变器、UPS、后备电源及各种直流电动设备)、汽车电瓶控制、电动汽车动力供电控制、直流电机控制、光伏供电系统及过欠压超限保护等。产品设计符合国家相关标准和电气安全规则,采用三位高亮LED数码管显示,继电器隔离输出,卡槽式安装方式,使您的产品更快地实现市场化。

 

      本继电器负载触点有三个接点(一组转换):公共点(COM)、常闭点(ON)、常开点(OFF),继电器不通电时,继电器释放,公共点和常闭点接通,当继电器线圈通电后继电器吸合,公共端和常开点就会接通

      继电器触点等同于开关,可用于交、直流用电系统控制回路中,此时继电器必须串联在回路中,不可将回路电源短路连接,触点最大负载电流为10A(DC30V/AC250V)。触点最大负载电流为10A(DC30V/AC250V),如果用于大于30V的直流控制回路中,需要增加相应电压等级的继电器,方可使用!!!  

   市面上的电压控制器层次不齐,功能乱并且操作复杂,很多功能都是多余的达不到客户的需求,本公司经过两年多的客户要求积累和经验开发出一款方便使用,实用,性价比高的电压控制器,集多种模式为一体,满足不同客户的需求。工作电压:直流12V,如需要24V或48V,请联系客服。
 
 
    下面为大家介绍一款我公司自主研发的多功电压控制器
     F1:自动充放电和电压滞回控制
     F2:电压超限动作模式(过压欠压保护)
     F3:电瓶自动放电控制
     F4:定时(延时)控制
     F5:手动控制
     以上所有功能的上下限报警值可调,报警延时时间可调(0.0-99.9秒、0-999秒、0-999分),可打开省电模式,数码管自动关闭,恢复默认参数 。
    下载电子版说明书(把网址复制到浏览器中打开):http://yunpan.taobao.com/s/2F45GXorNhE
     
     功能具体描述:
F1:自动充放电和电压滞回控制:
      功能说明:通过设定电压上、下限(过、欠压)及延时动作时间,来实现对电瓶的自动充放电管理;当电瓶电压低于设定下限值时,继电器延时动作(接通/断开),直到电瓶电压高于上限时,继电器再次延时动作(断开/接通)。
      应用范围:本功能属于电压滞回继电器控制;多用于电瓶充放电控制(逆变器、UPS、后备电源及各种直流电动设备)、汽车电瓶控制、电动汽车动力供电控制、直流电机控制、光伏供电系统等;例如:电压上限14.0V 下限11.5V,当电低于11.5V时继电器断开,直到电瓶电压高于14.5V继电器再吸合。
F2:电压超限动作模式(过压欠压保护):
      功能说明:通过设定电压上、下限(过、欠压)及延时动作时间,来实现对电压实时监测控制;当被测量电压低于设定下限值(欠压)或者高于设定上限值(过压)时,继电器延时动作(接通/断开);当被测量电压高于设定下限值(欠压)或者低于设定上限值(过压)时,继电器不动作(保持断开/接通)。
      应用范围:本功能主要实现电压超限保护或者控制,多用于各种直流电源、电瓶的超限控制,及电瓶单充电、单放电;(F1是电压上下限单向动作,而F2是双向动作), 此模式可用作过压欠压保护,例如:电压上限14.0V 下限11.5V,超过上限或下限时继电器均断开,电压在11.5-14.0V间则继电器吸接通。
F3:电瓶自动放电控制:
       功能说明:当下列两个条件中,任意一个条件满足时,继电器动作,终止放电:
      1、当放电电压到达设置值时,继电器断开,放电终止,显示放电时间;
      2、当放电时间到达设置值时,继电器断开,放电终止,显示放电终止电压。  
    应用范围:本功能是对电池放电容量进行测试控制,可以设定放电电压下限值和放电时间值;例如:对于12V的蓄电池来说,下限电压值设置为11V,放电时间设置为60分钟,这时蓄电池开始放电,当下限电压值先到时,放电终止,显示放电时间;当放电时间先到时,放电终止,显示放电终止电压。
F4:定时(延时)循环控制:
     功能说明1:继电器根据设定的接通和断开时间 进行定时循环动作,本功能不受监测电压控制。
    应用范围1:本功能主要用于继电器上电循环接通--断开或者断开--接通交替控制,接通、断开时间可以根据要求在999分钟内任意设定;多用于需要循环定时通断的控制系统中。
  功能说明2:继电器根据 设定的 上电接通(断开)后延时断开(接通) 时间进行定时动作,此功能不受监测电压控制。
   应用范围 2:本功能主要用于继电器上电定时接通或者定时断开,接通、断开时间可以根据要求在999分钟内任意设定;多用于需要定时通断的控制系统中; 如果需要设置为上电继电器接通,之后定时断开,需要将3-S中的SL设置为0; 如果需要设置为上电继电器断开,之后定时接通,需要将3-S中的SH设置为0。
F5:手动控制:
      功能说明: 本功能可对继电器进行手动控制。
 
      操作方法: 选择该模式后,在正常显示界面,短按U/D(操作键)对继电器进行接通或断开控制。注:本模式下,若设置自动关闭显示功能,唤醒显示则需要连续短按5次SET键,进行重启唤醒。
 
注释:
1、按键操作方法
(1)按键操作分为长按、短按、连续按;
  长按:按下按键3秒以上松开;
  短按:按下按键1秒内松开;
  连续短按:主显示界面,连续短按SET键5次,重新启动。
(2)按键定义
    SET(设置键):多用于菜单进入和参数保存退出;
   U/D(为操作键):多用于菜单项切换、参数选择、数字调节、手动开关显示以及手动开关继电器等。
 
2、参数设置操作:
(1)正常显示主界面→主菜单:长按SET键进入。
(2)主菜单→一级菜单:短按SET键进入。
(3)一级菜单→二级菜单:短按SET键进入。
(4)参数值保存、返回:长按SET键保存参数,并返回至上级菜单。
(5)参数移位:在设置多位数值的情况下,短按SET键,可移动要调节的数位。
(6)更改参数值或切换菜单项:短按U/D键。

1、外型尺寸:79*43*27mm、开孔尺寸:71.3*39.1mm,误差±1mm

2、工作电源:DC10-15V

3、电压检测及显示范围:DC:0-100V

4定时范围:0.0~99.9秒、0~999秒或0~999分钟(可任意选择);

5、待机电流:15mA/12V,继电器断开时最小10mA/12V,继电器吸合时45mA/12V;

6、工作环境温度:-40~85℃;

7、各种模式设定参数可断电保存,重新上电后继续上次模式执行。

8、电压上、下限闪烁报警;

9、继电器上电默认状态任意设定;

10、继电器参数:

  线圈额定工作电压:DC12V

  线圈最小释放电压:额定工作电压*75%

  线圈最大吸和电压:额定工作电压*90%

  线圈最大连续工作电压:额定工作电压*110%

  触点负载:DC30V/10A、AC250V/10A一组常开常闭转换

  触点接触电阻:100mΩMax

  触点吸和时间:10msec Max

  触点释放时间:5msec Max

  线圈与触点隔离电压:1.5KVAC/1minute

  隔离阻抗:100MΩMin. 500VDC

  触点机械耐久性:>1000万次

 
 

 

Characters

Properties

Brand

HZY

Model

H56UR

Whether to import

Processing and customization

Processing and customization

Processing and customization

Description

       本产品主要由智能直流电压表和直流继电器控制模块组成,既实现了对直流电压的精确测量,又可根据电压的上下限设定值、继电器动作延时值、计时时间和定时循环等参数进行多种组合,简单、灵活地实现了多种系统控制。广泛应用于电瓶充放电控制(逆变器、UPS、后备电源及各种直流电动设备)、汽车电瓶控制、电动汽车动力供电控制、直流电机控制、光伏供电系统及过欠压超限保护等。产品设计符合国家相关标准和电气安全规则,采用三位高亮LED数码管显示,继电器隔离输出,卡槽式安装方式,使您的产品更快地实现市场化。

 

      本继电器负载触点有三个接点(一组转换):公共点(COM)、常闭点(ON)、常开点(OFF),继电器不通电时,继电器释放,公共点和常闭点接通,当继电器线圈通电后继电器吸合,公共端和常开点就会接通

      继电器触点等同于开关,可用于交、直流用电系统控制回路中,此时继电器必须串联在回路中,不可将回路电源短路连接,触点最大负载电流为10A(DC30V/AC250V)。触点最大负载电流为10A(DC30V/AC250V),如果用于大于30V的直流控制回路中,需要增加相应电压等级的继电器,方可使用!!!  

   市面上的电压控制器层次不齐,功能乱并且操作复杂,很多功能都是多余的达不到客户的需求,本公司经过两年多的客户要求积累和经验开发出一款方便使用,实用,性价比高的电压控制器,集多种模式为一体,满足不同客户的需求。工作电压:直流12V,如需要24V或48V,请联系客服。
 
 
    下面为大家介绍一款我公司自主研发的多功电压控制器
     F1:自动充放电和电压滞回控制
     F2:电压超限动作模式(过压欠压保护)
     F3:电瓶自动放电控制
     F4:定时(延时)控制
     F5:手动控制
     以上所有功能的上下限报警值可调,报警延时时间可调(0.0-99.9秒、0-999秒、0-999分),可打开省电模式,数码管自动关闭,恢复默认参数 。
    下载电子版说明书(把网址复制到浏览器中打开):http://yunpan.taobao.com/s/2F45GXorNhE
     
     功能具体描述:
F1:自动充放电和电压滞回控制:
      功能说明:通过设定电压上、下限(过、欠压)及延时动作时间,来实现对电瓶的自动充放电管理;当电瓶电压低于设定下限值时,继电器延时动作(接通/断开),直到电瓶电压高于上限时,继电器再次延时动作(断开/接通)。
      应用范围:本功能属于电压滞回继电器控制;多用于电瓶充放电控制(逆变器、UPS、后备电源及各种直流电动设备)、汽车电瓶控制、电动汽车动力供电控制、直流电机控制、光伏供电系统等;例如:电压上限14.0V 下限11.5V,当电低于11.5V时继电器断开,直到电瓶电压高于14.5V继电器再吸合。
F2:电压超限动作模式(过压欠压保护):
      功能说明:通过设定电压上、下限(过、欠压)及延时动作时间,来实现对电压实时监测控制;当被测量电压低于设定下限值(欠压)或者高于设定上限值(过压)时,继电器延时动作(接通/断开);当被测量电压高于设定下限值(欠压)或者低于设定上限值(过压)时,继电器不动作(保持断开/接通)。
      应用范围:本功能主要实现电压超限保护或者控制,多用于各种直流电源、电瓶的超限控制,及电瓶单充电、单放电;(F1是电压上下限单向动作,而F2是双向动作), 此模式可用作过压欠压保护,例如:电压上限14.0V 下限11.5V,超过上限或下限时继电器均断开,电压在11.5-14.0V间则继电器吸接通。
F3:电瓶自动放电控制:
       功能说明:当下列两个条件中,任意一个条件满足时,继电器动作,终止放电:
      1、当放电电压到达设置值时,继电器断开,放电终止,显示放电时间;
      2、当放电时间到达设置值时,继电器断开,放电终止,显示放电终止电压。  
    应用范围:本功能是对电池放电容量进行测试控制,可以设定放电电压下限值和放电时间值;例如:对于12V的蓄电池来说,下限电压值设置为11V,放电时间设置为60分钟,这时蓄电池开始放电,当下限电压值先到时,放电终止,显示放电时间;当放电时间先到时,放电终止,显示放电终止电压。
F4:定时(延时)循环控制:
     功能说明1:继电器根据设定的接通和断开时间 进行定时循环动作,本功能不受监测电压控制。
    应用范围1:本功能主要用于继电器上电循环接通--断开或者断开--接通交替控制,接通、断开时间可以根据要求在999分钟内任意设定;多用于需要循环定时通断的控制系统中。
  功能说明2:继电器根据 设定的 上电接通(断开)后延时断开(接通) 时间进行定时动作,此功能不受监测电压控制。
   应用范围 2:本功能主要用于继电器上电定时接通或者定时断开,接通、断开时间可以根据要求在999分钟内任意设定;多用于需要定时通断的控制系统中; 如果需要设置为上电继电器接通,之后定时断开,需要将3-S中的SL设置为0; 如果需要设置为上电继电器断开,之后定时接通,需要将3-S中的SH设置为0。
F5:手动控制:
      功能说明: 本功能可对继电器进行手动控制。
 
      操作方法: 选择该模式后,在正常显示界面,短按U/D(操作键)对继电器进行接通或断开控制。注:本模式下,若设置自动关闭显示功能,唤醒显示则需要连续短按5次SET键,进行重启唤醒。
 
注释:
1、按键操作方法
(1)按键操作分为长按、短按、连续按;
  长按:按下按键3秒以上松开;
  短按:按下按键1秒内松开;
  连续短按:主显示界面,连续短按SET键5次,重新启动。
(2)按键定义
    SET(设置键):多用于菜单进入和参数保存退出;
   U/D(为操作键):多用于菜单项切换、参数选择、数字调节、手动开关显示以及手动开关继电器等。
 
2、参数设置操作:
(1)正常显示主界面→主菜单:长按SET键进入。
(2)主菜单→一级菜单:短按SET键进入。
(3)一级菜单→二级菜单:短按SET键进入。
(4)参数值保存、返回:长按SET键保存参数,并返回至上级菜单。
(5)参数移位:在设置多位数值的情况下,短按SET键,可移动要调节的数位。
(6)更改参数值或切换菜单项:短按U/D键。

1、外型尺寸:79*43*27mm、开孔尺寸:71.3*39.1mm,误差±1mm

2、工作电源:DC10-15V

3、电压检测及显示范围:DC:0-100V

4定时范围:0.0~99.9秒、0~999秒或0~999分钟(可任意选择);

5、待机电流:15mA/12V,继电器断开时最小10mA/12V,继电器吸合时45mA/12V;

6、工作环境温度:-40~85℃;

7、各种模式设定参数可断电保存,重新上电后继续上次模式执行。

8、电压上、下限闪烁报警;

9、继电器上电默认状态任意设定;

10、继电器参数:

  线圈额定工作电压:DC12V

  线圈最小释放电压:额定工作电压*75%

  线圈最大吸和电压:额定工作电压*90%

  线圈最大连续工作电压:额定工作电压*110%

  触点负载:DC30V/10A、AC250V/10A一组常开常闭转换

  触点接触电阻:100mΩMax

  触点吸和时间:10msec Max

  触点释放时间:5msec Max

  线圈与触点隔离电压:1.5KVAC/1minute

  隔离阻抗:100MΩMin. 500VDC

  触点机械耐久性:>1000万次

 
 

 

From this seller