Automatic cement Boshi c/FBT-5 type FBT-9 type accessories/accessories/perforated plate
Automatic cement Boshi c/FBT-5 type FBT-9 type accessories/accessories/perforated plate
Automatic cement Boshi c/FBT-5 type FBT-9 type accessories/accessories/perforated plate
Automatic cement Boshi c/FBT-5 type FBT-9 type accessories/accessories/perforated plate

Automatic cement Boshi c/FBT-5 type FBT-9 type accessories/accessories/perforated plate

5.0
1 sold.
Minimum quantity is: 1 pcs

Price from:

94,042 so'm

Guaranteed delivery time

If we are 45 days late, you will receive your order for free. More details

Always in touch with you

We will answer any questions every day.

Secure payment in a convenient way

We will accept payment by any card

BNPL available

Uzum
select product
inTend
select product
Select payment by installments when placing your order. The final installment cost is calculated at checkout.
Automatic cement Boshi c/FBT-5 type FBT-9 type accessories/accessories/perforated plate

About the product

Characteristic

Origin

Mainland China

Product Use

Cement specific surface area tester

Color

Liquid Crystal Display type, digital display type,

Item No.

/FBT-5 type FBT-9

Type

Specific surface area tester

Brand

Zhengmei

Model

/FBT-5 type FBT-9

Import or not

No

Customized processing

No

Inner size

1

Outer size

1

Order Number

bml-636

Description

----------全自动水泥勃氏比表面积测定仪/FBT-5型FBT-9型配件/附件/穿孔板----------

使用说明:

一.检测前的准备工作

 1.被测试样烘干备用;

2.预先测定好被测试样的密度;

3.AC220V、50Hz+10%的电源;

4.1%天平一台;

5.少许黄油;

 6.将仪器放平稳,接通电源,打开仪器左侧的电源开关。此时仪器显示1区显示“Err1”,表示压力计内的水平位未达到最底刻度线。用滴定管从压力计左侧一滴一滴的滴入请水,滴水的过程中仔细观察显示屏,如显示平屏出现S值、K值、温度值,请停止滴水。此时仪器处于待机状态;如超过刻度线,请倒出水,然后按上述的操作使仪器处于待机状态,再进行测量。

二.仪器常数K值的标定

1.需要的已知的参数

1)标准试样的比表面积;

2)标准试样的密度;

3)容捅的标称体积。

2.试样的制备

1)标准试样需在110+5℃下烘干3小时以上。在干燥中冷却至室温。

2)按公式WS=ρS×V×(1—εS)计算试样量。其中ρS—标准试样的密度;V—容桶的标称体积;εS—标准试样的空隙率(注:本仪器标准试样及初测试样的空隙率均为0.5)

3)例:标准试样密度3.16;容桶体积1.980;空隙率0.5。

WS=ρS×V×(1—εS)=3.16×1.980×(1—0.5)=3.1284(g)

请称重已烘干并冷却的标准试样3.1284g.

3.将容捅放在金属支架上,放入穿孔板,用推杆将穿孔板放平,再放入一片滤纸,用推杆按到底部平整即可。通过漏斗将标准试样装入容桶(切忌不要振动容桶),用手轻摆容桶将标准试样表面基本摆平。再放入一片滤纸,用捣器轻轻边旋边将滤纸推入容桶至捣器与容桶完全闭合。从支架上取下容桶,在容桶锥部的下部均匀涂上少许黄油。将容桶边旋边放入玻璃压力计的锥口部分,观察容桶外壁与压力计内壁间应有均匀的黄油密封层即可。

4.仪器的K值的标定,请参照操作说明中的K值的测量。

压力计保险管的更换

1.压力计的更换;把固定压力计的4个螺丝卸下,卸下已损坏的压力计上的胶管。把新的压力计用于螺丝固定的部位用医用胶布包好(包扎的圈数可按照换下的压力计的圈数),插上胶官,然后把压力计放到固定夹子上,调整好高度(压力计右端的3条刻度线分别与光电开关的1、2、3平齐或稍下方)再用螺丝固定。更换好压力计后,请参照使用说明书检查漏气。

2.保险管的更换

保险管在仪器的左侧电源插座内,先拔掉电源线,用小一字起子把插座内T形方块撬出,取下已损坏的保险管,然后换上新的规格5×20/1A的保险管,再把T形管推入座内。

 

 

Characters

Properties

Origin

Mainland China

Product Use

Cement specific surface area tester

Color

Liquid Crystal Display type, digital display type,

Item No.

/FBT-5 type FBT-9

Description

----------全自动水泥勃氏比表面积测定仪/FBT-5型FBT-9型配件/附件/穿孔板----------

使用说明:

一.检测前的准备工作

 1.被测试样烘干备用;

2.预先测定好被测试样的密度;

3.AC220V、50Hz+10%的电源;

4.1%天平一台;

5.少许黄油;

 6.将仪器放平稳,接通电源,打开仪器左侧的电源开关。此时仪器显示1区显示“Err1”,表示压力计内的水平位未达到最底刻度线。用滴定管从压力计左侧一滴一滴的滴入请水,滴水的过程中仔细观察显示屏,如显示平屏出现S值、K值、温度值,请停止滴水。此时仪器处于待机状态;如超过刻度线,请倒出水,然后按上述的操作使仪器处于待机状态,再进行测量。

二.仪器常数K值的标定

1.需要的已知的参数

1)标准试样的比表面积;

2)标准试样的密度;

3)容捅的标称体积。

2.试样的制备

1)标准试样需在110+5℃下烘干3小时以上。在干燥中冷却至室温。

2)按公式WS=ρS×V×(1—εS)计算试样量。其中ρS—标准试样的密度;V—容桶的标称体积;εS—标准试样的空隙率(注:本仪器标准试样及初测试样的空隙率均为0.5)

3)例:标准试样密度3.16;容桶体积1.980;空隙率0.5。

WS=ρS×V×(1—εS)=3.16×1.980×(1—0.5)=3.1284(g)

请称重已烘干并冷却的标准试样3.1284g.

3.将容捅放在金属支架上,放入穿孔板,用推杆将穿孔板放平,再放入一片滤纸,用推杆按到底部平整即可。通过漏斗将标准试样装入容桶(切忌不要振动容桶),用手轻摆容桶将标准试样表面基本摆平。再放入一片滤纸,用捣器轻轻边旋边将滤纸推入容桶至捣器与容桶完全闭合。从支架上取下容桶,在容桶锥部的下部均匀涂上少许黄油。将容桶边旋边放入玻璃压力计的锥口部分,观察容桶外壁与压力计内壁间应有均匀的黄油密封层即可。

4.仪器的K值的标定,请参照操作说明中的K值的测量。

压力计保险管的更换

1.压力计的更换;把固定压力计的4个螺丝卸下,卸下已损坏的压力计上的胶管。把新的压力计用于螺丝固定的部位用医用胶布包好(包扎的圈数可按照换下的压力计的圈数),插上胶官,然后把压力计放到固定夹子上,调整好高度(压力计右端的3条刻度线分别与光电开关的1、2、3平齐或稍下方)再用螺丝固定。更换好压力计后,请参照使用说明书检查漏气。

2.保险管的更换

保险管在仪器的左侧电源插座内,先拔掉电源线,用小一字起子把插座内T形方块撬出,取下已损坏的保险管,然后换上新的规格5×20/1A的保险管,再把T形管推入座内。

 

 