QJ36a DC Digital dual-arm Bridge experimental instrument
QJ36a DC Digital dual-arm Bridge experimental instrument
QJ36a DC Digital dual-arm Bridge experimental instrument
QJ36a DC Digital dual-arm Bridge experimental instrument
QJ36a DC Digital dual-arm Bridge experimental instrument

QJ36a DC Digital dual-arm Bridge experimental instrument

0.0
1 sold.
Minimum quantity is: 1 pcs

Price from:

56,189,617 so'm

Guaranteed delivery time

If we are 45 days late, you will receive your order for free. More details

Always in touch with you

We will answer any questions every day.

Secure payment in a convenient way

We will accept payment by any card

BNPL available

Uzum
select product
inTend
select product
Select payment by installments when placing your order. The final installment cost is calculated at checkout.
QJ36a DC Digital dual-arm Bridge experimental instrument

About the product

Characteristic

Origin

Fuyang District, Hangzhou city, China

Capacitance measurement range

No capacitance measurement range

Resistance measurement range

0.001Ω-200Ω seven-gear range

Item No.

1

Type

DC Digital Display Bridge

Brand

Ningfang Electronics

Weight

7

Accuracy level

0.1 0.2 0.005 0.005 0.005 0.005 0.005

Import or not

No

Customized processing

No

Order Number

0

Description

 

如果QJ36a电桥需要测量电线电缆,那么再购买我公司生产的一台夹具,只要再配一台夹具就可以测量电线电缆了,关于QJ36a配的电线的电阻值在1Ω以下,QJ36a的测试电压是3V

 

 

一、用

QJ36a直流数字双臂电桥是一种由高稳定精密恒流源、带自校的高精度数字电压表和CPU微处理器组成的5位半台式数字式直流电阻测试仪,其测量结果用6位VFD荧光显示。该仪器具有价格低廉、测量精度高、性能稳、使用方便等特点,它适用于测量各种电线、电缆的电阻值、各类线圈、电动机、变压器绕组的电阻,特别是具有自校功能(用户备用BZ3标准电阻,就可以校准),提高仪器的精度,省去了操作人员的送检时间。因此该仪器广泛应用工厂、科研单位的工作场地和实验室。

二、技术指标

2.1   使用条件:

2.1.1环境温度:20±15℃(校准温度:20±1℃)

2.1.2相对湿度:不大于75%RH

2.1.3供电电源:220V±10%,50Hz±1Hz

2.1.4无剧烈震动和机械冲击

2.1.5环境周围无强电磁场干扰

2.1.6空气中不含腐蚀气体、灰尘和有害杂质

2.1.7通风条件良好

2.1.8总技术指标

 

型号

QJ36a直流数字双臂电桥

测量范围

0.001μΩ-200Ω档量程

最小分辨力

0.001μΩ

量程

测量范围

分辨力

测试电流可换向)

准确度等级

电流倍率

200μΩ

0-199.999μΩ

0.001μΩ

±10A

0.2%

0.707/1/1.414

2 

0-1.99999mΩ

0.01μΩ

±10A

0.1%

0.707/1/1.414

20

0-19.9999mΩ

0. 1μΩ

±1A

0.05%

0.707/1/1.414

200 mΩ

0-199.999

1μΩ

±0.1A

0.05%

0.707/1/1.414

0-1.99999Ω

10μΩ

±0.01A

0.05%

0.707/1/1.414

 20Ω

0-19.9999Ω

100μΩ

±1 mA

0.05%

0.707/1/1.414

200Ω

 0-199.999Ω

1mΩ

±0.1mA

0.05%

0.707/1/1.414

显示

5½ 荧光显示

电源

220V供电 功耗25W

尺寸

(W)450 mm×(H)150 mm×(D)400mm

温度补偿

15.0℃~25.0

重量

7kg

                                    

2.2   量程、测量范围、分辨力及基本误差

产品在标准条件(20±1℃)下符合表 1规定

1

量程

测量范围

分辨力

测试电流

基本误差

200μΩ

199.999μΩ

0.001μΩ

10A

±(0.2%读数值+3字)

2mΩ

1.99999mΩ

0.01μΩ

10A

±(0.1%读数值+3字)

20mΩ

19.9999mΩ

0.1μΩ

1A

±(0.05%读数值+3字)

200mΩ

199.999mΩ

1μΩ

0.1A

1.99999Ω

10μΩ

10mA

±(0.05%读数值+3字)

20Ω

19.9999Ω

100μΩ

1mA

200Ω

199.999Ω

1 mΩ

0.1 mA

±(0.05%读数值+3字)

 

2.3   温度的影响

产品在(20±5℃)条件下,误差如表 2所示

2

量程

测量范围

分辨力

测试电流

基本误差

200μΩ

199.999μΩ

0.001μΩ

10A

±(0.3%读数值+3字)

2mΩ

1.99999mΩ

0.01μΩ

10A

±(0.2%读数值+3字)

20mΩ

19.9999mΩ

0.1μΩ

1A

±(0.1%读数值+3字)

2mΩ

199.999mΩ

1μΩ

0.1A

±(0.1%读数值+2字)

1.99999Ω

10μΩ

0.01A

20Ω

19.9999Ω

100μΩ

1mA

200Ω

199.999Ω

0.1mΩ

0.1mA

如用BZ3标准电阻进行现场标定,QJ36a的精度可以大大提高

2.4    温度附加误差

产品在偏离20±1℃的情况下工作,环境温度每变化多端10℃所引起的附加误差应不超出基本误差值。

2.5   倍功率的影响(×0.707I×1.414I

产品在(20±5℃)条件下,误差如表 2所示

2

量程

测量范围

分辨力

测试电流

基本误差

200μΩ

199.999μΩ

0.001μΩ

10A

±(0.3%读数值+10字)

2mΩ

1.99999mΩ

0.01μΩ

10A

±(0.2%读数值+10字)

20mΩ

19.9999mΩ

0.1μΩ

1A

±(0.1%读数值+10字)

2mΩ

199.999mΩ

1μΩ

0.1A

±(0.1%读数值+5字)

1.99999Ω

10μΩ

0.01A

20Ω

19.9999Ω

100μΩ

1mA

200Ω

199.999Ω

0.1mΩ

0.1mA

 

2.6    极性、量程过载指示

2.6.1在电阻测量时不显示极性

2.6.2当输入电阻值超过仪表测量范围时仪表显示 <LCE>

2.7    采样速度:2~3次/s

2.8    消耗功率:≤30W

29    重量:≤7kg

 undefined

undefined

undefined

undefined

200μΩ档,  电流端C1  、C2端可输出      10A电流

2mΩ档,     电流端C1  、C2端可输出      10A电流

20mΩ档,    电流端C1  、C2端可输出      1A电流

200mΩ档,   电流端C1  、C2端可输出      0.1A电流

2Ω档,      电流端C1  、C2端可输出      0.01A电流

20Ω档,     电流端C1  、C2端可输出      1mA电流

200Ω档,    电流端C1  、C2端可输出      0.1mA电流

4.2.5   正反向测试电流的用法

在测量微欧姆电阻时,建议正向电流测量一次,记录测试结果。再进行反向测试电流测量一次,记录测试结果。两次数值的平均就是被测物的电阻值。

4.2.6   倍功率测试电流的用法

按照电线电缆国家标准,其中有一项倍功率对被测物的影响,众所周知

            P=I2R

半倍功率;Ib=0.707I

一倍功率;Ip=1.414I

使用倍功率时,本仪器的精度:0.1%

4.2.7   温度补偿的用法

按照电线电缆国家标准,其中有电阻率的数据是要折算到20℃这一点上。一般用QJ36a对电线电缆测试的环境温度不再这一点上,本仪器为了方便使用特增加温度补偿开关,使用者可根据环境温度值,设置到QJ36a的温度补偿开关温度值上,此时QJ36a上的读数已经是转换到20℃时的被测电阻的电阻值。省去使用者计算。

使用温度补偿时,本仪器的精度:0.1%。

五、维护和复核

为了保证仪表的使用正确性,必须定期对它进行复核维护和调节。此时温度补偿置于断的位置。

5.1  复核 所需设备:

⑴ 0.01%精度直流标准电阻一套(0.001Ω、0.01Ω、0.1Ω、1Ω、10Ω、100Ω)

⑵ 0.01%精度直流电阻箱一台(0~200Ω)

 

 

 

 

 undefined

 

 

步骤

量程按键

测试/停止

按键

显示屏

1

2Ω档按下

按下

标定

2

888888

888888

3

输入

CAL

4

输入

内码

5

输入

0.00000

6

弹出

 

1.00000(左右)

7

输入

0.00000

8

输入电阻实际值,如1.00 002

1.00002

9

输入

(完成,显示实测值)

② 用微欧计专用电阻箱进行标定。

5.2   维护和调节

在用户不具备复核校对或用户复核值超出基本误差,生产厂家可免费为用户对产品进行复校维护和调节。

 成套性

6.1     随同产品一起供应的技术文件有:

6.1.1  产品合格证      1份粘贴在仪器上面

6.1.2  使用说明书      1份

6.2     随同产品一起供应的附件有

6.2.1  输入线           1付

6.2.2  电源线           1根

 

 

七、   保用期

仪器存放在环境温度为0~40℃,相对湿度不大于80%,空气不应含有腐蚀仪器的气体和有害杂质。仪器和附件自制造厂发货日起12个月内,当用户完遵守保管和使用规则的条件下,且原出厂封印仍完整,出现仪器不能正常工作现象,制造厂负责免费为用户修理乃至更换产品。如属人为或自行拆机,均由用户负责,本公司修理收取材料费和人工费与运费。

 

注:在使用本产品前,请您仔细阅读该使用说明书,并请妥善保管,以备将来查阅。

仪器箱体变动不另行通知,仪器设计改变不另行通知。可以电话与微信与QQ上沟通,

 

 

 

 

 

 

Characters

Properties

Origin

Fuyang District, Hangzhou city, China

Capacitance measurement range

No capacitance measurement range

Resistance measurement range

0.001Ω-200Ω seven-gear range

Item No.

1

Description

 

如果QJ36a电桥需要测量电线电缆,那么再购买我公司生产的一台夹具,只要再配一台夹具就可以测量电线电缆了,关于QJ36a配的电线的电阻值在1Ω以下,QJ36a的测试电压是3V

 

 

一、用

QJ36a直流数字双臂电桥是一种由高稳定精密恒流源、带自校的高精度数字电压表和CPU微处理器组成的5位半台式数字式直流电阻测试仪,其测量结果用6位VFD荧光显示。该仪器具有价格低廉、测量精度高、性能稳、使用方便等特点,它适用于测量各种电线、电缆的电阻值、各类线圈、电动机、变压器绕组的电阻,特别是具有自校功能(用户备用BZ3标准电阻,就可以校准),提高仪器的精度,省去了操作人员的送检时间。因此该仪器广泛应用工厂、科研单位的工作场地和实验室。

二、技术指标

2.1   使用条件:

2.1.1环境温度:20±15℃(校准温度:20±1℃)

2.1.2相对湿度:不大于75%RH

2.1.3供电电源:220V±10%,50Hz±1Hz

2.1.4无剧烈震动和机械冲击

2.1.5环境周围无强电磁场干扰

2.1.6空气中不含腐蚀气体、灰尘和有害杂质

2.1.7通风条件良好

2.1.8总技术指标

 

型号

QJ36a直流数字双臂电桥

测量范围

0.001μΩ-200Ω档量程

最小分辨力

0.001μΩ

量程

测量范围

分辨力

测试电流可换向)

准确度等级

电流倍率

200μΩ

0-199.999μΩ

0.001μΩ

±10A

0.2%

0.707/1/1.414

2 

0-1.99999mΩ

0.01μΩ

±10A

0.1%

0.707/1/1.414

20

0-19.9999mΩ

0. 1μΩ

±1A

0.05%

0.707/1/1.414

200 mΩ

0-199.999

1μΩ

±0.1A

0.05%

0.707/1/1.414

0-1.99999Ω

10μΩ

±0.01A

0.05%

0.707/1/1.414

 20Ω

0-19.9999Ω

100μΩ

±1 mA

0.05%

0.707/1/1.414

200Ω

 0-199.999Ω

1mΩ

±0.1mA

0.05%

0.707/1/1.414

显示

5½ 荧光显示

电源

220V供电 功耗25W

尺寸

(W)450 mm×(H)150 mm×(D)400mm

温度补偿

15.0℃~25.0

重量

7kg

                                    

2.2   量程、测量范围、分辨力及基本误差

产品在标准条件(20±1℃)下符合表 1规定

1

量程

测量范围

分辨力

测试电流

基本误差

200μΩ

199.999μΩ

0.001μΩ

10A

±(0.2%读数值+3字)

2mΩ

1.99999mΩ

0.01μΩ

10A

±(0.1%读数值+3字)

20mΩ

19.9999mΩ

0.1μΩ

1A

±(0.05%读数值+3字)

200mΩ

199.999mΩ

1μΩ

0.1A

1.99999Ω

10μΩ

10mA

±(0.05%读数值+3字)

20Ω

19.9999Ω

100μΩ

1mA

200Ω

199.999Ω

1 mΩ

0.1 mA

±(0.05%读数值+3字)

 

2.3   温度的影响

产品在(20±5℃)条件下,误差如表 2所示

2

量程

测量范围

分辨力

测试电流

基本误差

200μΩ

199.999μΩ

0.001μΩ

10A

±(0.3%读数值+3字)

2mΩ

1.99999mΩ

0.01μΩ

10A

±(0.2%读数值+3字)

20mΩ

19.9999mΩ

0.1μΩ

1A

±(0.1%读数值+3字)

2mΩ

199.999mΩ

1μΩ

0.1A

±(0.1%读数值+2字)

1.99999Ω

10μΩ

0.01A

20Ω

19.9999Ω

100μΩ

1mA

200Ω

199.999Ω

0.1mΩ

0.1mA

如用BZ3标准电阻进行现场标定,QJ36a的精度可以大大提高

2.4    温度附加误差

产品在偏离20±1℃的情况下工作,环境温度每变化多端10℃所引起的附加误差应不超出基本误差值。

2.5   倍功率的影响(×0.707I×1.414I

产品在(20±5℃)条件下,误差如表 2所示

2

量程

测量范围

分辨力

测试电流

基本误差

200μΩ

199.999μΩ

0.001μΩ

10A

±(0.3%读数值+10字)

2mΩ

1.99999mΩ

0.01μΩ

10A

±(0.2%读数值+10字)

20mΩ

19.9999mΩ

0.1μΩ

1A

±(0.1%读数值+10字)

2mΩ

199.999mΩ

1μΩ

0.1A

±(0.1%读数值+5字)

1.99999Ω

10μΩ

0.01A

20Ω

19.9999Ω

100μΩ

1mA

200Ω

199.999Ω

0.1mΩ

0.1mA

 

2.6    极性、量程过载指示

2.6.1在电阻测量时不显示极性

2.6.2当输入电阻值超过仪表测量范围时仪表显示 <LCE>

2.7    采样速度:2~3次/s

2.8    消耗功率:≤30W

29    重量:≤7kg

 undefined

undefined

undefined

undefined

200μΩ档,  电流端C1  、C2端可输出      10A电流

2mΩ档,     电流端C1  、C2端可输出      10A电流

20mΩ档,    电流端C1  、C2端可输出      1A电流

200mΩ档,   电流端C1  、C2端可输出      0.1A电流

2Ω档,      电流端C1  、C2端可输出      0.01A电流

20Ω档,     电流端C1  、C2端可输出      1mA电流

200Ω档,    电流端C1  、C2端可输出      0.1mA电流

4.2.5   正反向测试电流的用法

在测量微欧姆电阻时,建议正向电流测量一次,记录测试结果。再进行反向测试电流测量一次,记录测试结果。两次数值的平均就是被测物的电阻值。

4.2.6   倍功率测试电流的用法

按照电线电缆国家标准,其中有一项倍功率对被测物的影响,众所周知

            P=I2R

半倍功率;Ib=0.707I

一倍功率;Ip=1.414I

使用倍功率时,本仪器的精度:0.1%

4.2.7   温度补偿的用法

按照电线电缆国家标准,其中有电阻率的数据是要折算到20℃这一点上。一般用QJ36a对电线电缆测试的环境温度不再这一点上,本仪器为了方便使用特增加温度补偿开关,使用者可根据环境温度值,设置到QJ36a的温度补偿开关温度值上,此时QJ36a上的读数已经是转换到20℃时的被测电阻的电阻值。省去使用者计算。

使用温度补偿时,本仪器的精度:0.1%。

五、维护和复核

为了保证仪表的使用正确性,必须定期对它进行复核维护和调节。此时温度补偿置于断的位置。

5.1  复核 所需设备:

⑴ 0.01%精度直流标准电阻一套(0.001Ω、0.01Ω、0.1Ω、1Ω、10Ω、100Ω)

⑵ 0.01%精度直流电阻箱一台(0~200Ω)

 

 

 

 

 undefined

 

 

步骤

量程按键

测试/停止

按键

显示屏

1

2Ω档按下

按下

标定

2

888888

888888

3

输入

CAL

4

输入

内码

5

输入

0.00000

6

弹出

 

1.00000(左右)

7

输入

0.00000

8

输入电阻实际值,如1.00 002

1.00002

9

输入

(完成,显示实测值)

② 用微欧计专用电阻箱进行标定。

5.2   维护和调节

在用户不具备复核校对或用户复核值超出基本误差,生产厂家可免费为用户对产品进行复校维护和调节。

 成套性

6.1     随同产品一起供应的技术文件有:

6.1.1  产品合格证      1份粘贴在仪器上面

6.1.2  使用说明书      1份

6.2     随同产品一起供应的附件有

6.2.1  输入线           1付

6.2.2  电源线           1根

 

 

七、   保用期

仪器存放在环境温度为0~40℃,相对湿度不大于80%,空气不应含有腐蚀仪器的气体和有害杂质。仪器和附件自制造厂发货日起12个月内,当用户完遵守保管和使用规则的条件下,且原出厂封印仍完整,出现仪器不能正常工作现象,制造厂负责免费为用户修理乃至更换产品。如属人为或自行拆机,均由用户负责,本公司修理收取材料费和人工费与运费。

 

注:在使用本产品前,请您仔细阅读该使用说明书,并请妥善保管,以备将来查阅。

仪器箱体变动不另行通知,仪器设计改变不另行通知。可以电话与微信与QQ上沟通,

 

 

 

 

 

 

From this seller